Baijia.net - a professional third-party testing and inspection platform that provides testing services for beverages, bottled water, and other related
6.3 Instruments and equipment 6.3.1 pH meter: measuring range 0-14, reading accuracy ≤ 0.02. 6.3.2 Glass electrodes. 6.3.3- Saturated calomel electrode. 6.4 Analysis Step 6.4.1 Glass electrodes should be immersed in water for at least 24 hours before use. 6.4.2 Instrument calibration: After the instrument is turned on for 0.5 hours, follow the instrument manual to perform zero adjustment, temperature compensation, and full scale calibration. 6.4.3 pH positioning: Select a standard buffer solution that is close to the pH of the tested water sample, repeat positioning 1-2 times, and when the pH of the water sample< At 7,0, use potassium hydrogen phthalate buffer solution for positioning, and use sodium tetraborate standard buffer solution or mixed phosphate buffer solution for re positioning; Water sample pH> At 7.0, use sodium tetraborate buffer solution for localization, and use potassium hydrogen phthalate buffer solution or mixed phosphate buffer solution for re localization. 6.4.4. Slowly rinse the 2 electrodes with water several times using a washing bottle, then rinse the water sample 6-8 times, and insert it into the water sample. After 1 minute, directly read the pH from the instrument. Note 1. When the room temperature rises, the saturated potassium chloride solution inside the calomel electrode may change from a saturated state to an unsaturated state, so a certain amount of potassium chloride crystals should be maintained inside the electrode. Note 2: For solutions with a pH greater than 9, a high alkali glass electrode should be used to measure the pH. 7. Soluble Total Solids 7.1105 ℃ Drying Gravimetric Method 7.1.1 Principle Soluble Total Solids is the total amount of inorganic mineral components dissolved in water. The water sample is filtered through a 0.45 pm filter membrane to remove suspended solids. A certain volume of filtrate is evaporated to dryness, and dried at 105 ℃ to constant weight. The evaporation residue content can be measured. The dissolved solid content is added to half of the bicarbonate content (bicarbonate decomposes and loses carbon dioxide during drying and converts into carbonate) to form the total dissolved solid
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms
3. Used as a sales report: issuing legally effective testing reports to make consumers more confident
4. Papers and research: Provide professional personalized testing needs
5. Judicial services: providing scientific, fair, and accurate testing data
6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems
BAIJIAN testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations
3. Mail samples and arrange testing
4. Progress tracking and result feedback
5. Provide reports and after-sales service
6. If urgent or priority processing is required
Our Competitive Edge:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby
3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service
7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc
8. The testing report is authoritative and effective, and is generally used in China
Contact: Mr. Li
Phone: 156-0190-2607
Tel: 400-101-7153
Email: service@Baijiantest.com
Add: No. 700, Yishan Road, Xuhui District, Shangha