Baijia.net - a professional third-party testing and inspection platform that provides testing services for agricultural products (vegetables, fruits),
6.4.1 Chromatographic reference conditions 6.4.1.1 Chromatographic column pre column: 1.0 m, 0.53 mm inner diameter, deactivated quartz capillary column. Two chromatographic columns, respectively; A-column: 50% polyphenylmethylsiloxane (DB-17 or HP-50+) 'column, 30 m × 0.53 mm × 1.0 um, or equivalent; B-column: l100% polymethyl siloxane (DB-1 or HP-1) 'column, 30 m × 0.53 mm × 1.50 um, or equivalent. 6.4.1.2 Temperature of the sample inlet: 220 ℃. Detector temperature: 250 ℃. Column temperature: 150 ℃ (maintained for 2 minutes) -, BC/min. 250 ℃ (maintained for 12 minutes). 6.4.1.3 Gas and flow carrier gas; Nitrogen, purity ≥ 99.999%, flow rate of 10 mL/min. Gas; Hydrogen gas, purity ≥ 99.999%, flow rate of 75 mL/min. auxiliary gas; Air, with a flow rate of 100 ml/min. 6.4.1.4 Injection method: Non split injection. The sample solution is in duplicate and injected simultaneously by a dual automatic sampler. 6.4.2 Chromatographic analysis: 1.0 pL. standard mixed solution and purified sample solution are respectively aspirated by an automatic sampler and injected into the chromatograph. Qualitative analysis is performed using dual column retention time, and the peak area of the sample solution obtained from column A is compared with the peak area of the standard solution for quantification. 7 Result expression 7.1 Qualitative analysis: Compare the retention time (RT) of unknown components in the sample solution measured by two columns with the retention time (RT) of the standard solution on the same chromatographic column. If the retention time of two groups of a certain component in the sample solution is within ± 0.05 minutes of the retention time of two groups of a certain pesticide in the standard solution, it can be considered as the pesticide
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms
3. Used as a sales report: issuing legally effective testing reports to make consumers more confident
4. Papers and research: Provide professional personalized testing needs
5. Judicial services: providing scientific, fair, and accurate testing data
6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems
BAIJIAN testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations
3. Mail samples and arrange testing
4. Progress tracking and result feedback
5. Provide reports and after-sales service
6. If urgent or priority processing is required
Our Competitive Edge:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby
3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service
7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc
8. The testing report is authoritative and effective, and is generally used in China
Contact: Mr. Li
Phone: 156-0190-2607
Tel: 400-101-7153
Email: service@Baijiantest.com
Add: No. 700, Yishan Road, Xuhui District, Shangha