Popular Food Testing


Detection of illegally added parameters in dairy products

Baijia.net - a professional third-party testing and inspection platform that provides related testing and inspection services such as illegal addition
Product Description:

1. Scope: This standard specifies the raw milk Three determination methods for melamine in dairy products and dairy products, including high-performance liquid chromatography (HPLC), liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS), and gas chromatography-mass spectrometry (GC-MS) [including gas chromatography-mass spectrometry (GC-MS), gas chromatography-mass spectrometry/mass spectrometry (GC-S/MS)] This standard is applicable to the quantitative determination of melamine in raw milk, dairy products, and dairy products; The liquid chromatography-mass spectrometry/mass spectrometry method and gas chromatography-mass spectrometry (including gas chromatography-mass spectrometry/mass spectrometry) are both applicable to the qualitative confirmation of melamine in raw milk, dairy products, and dairy products. The quantitative limit of this standard for high-performance liquid chromatography is 2 mg/kg, and the quantitative limit for liquid chromatography-mass spectrometry/mass spectrometry is 0.01 mg/kg. The quantitative limit for gas chromatography-mass spectrometry is 0.05 mg/kg (of which the quantitative limit for gas chromatography-mass spectrometry/mass spectrometry is 0.005 mg/kg). 2 Normative References: The clauses in the following documents become clauses of this standard through reference in this standard. For dated reference documents, all subsequent amendments (excluding errors) or revisions are not applicable to this standard. However, parties to agreements based on this standard are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest version applies to this standard. GB/T 6682 Specification and Test Methods for Analytical Laboratory Water (GB/T 6682-2008, ISO 3696; 1987, MOD) 3 First Method: High Performance Liquid Chromatography (HPLC) 3.1 Principle: The sample is extracted with trichloroacetic acid solution acetonitrile, purified by a cation exchange solid-phase extraction column, determined by HPLC, and quantified by external standard method. 3.2 Reagents and Materials Unless otherwise specified, all reagents are analytical pure, and water is Grade 1 water as specified in GB/T 6682. 3.2.1 Jia Zui: The color is harmonious and pure. 3.2.2 Acetonitrile: Chromatically pure. 3.2.3 Ammonia water: The content is 25%~28%. 3.2.4 Trichloroacetic acid. 3.2.5 Citric acid. 3.2.6 Sodium octane sulfonate; Chromatographic purity. 3.2.7 Methanol aqueous solution: Accurately measure 50 mL of methanol and 50 mL of water, mix well, and set aside. 3.2.8 Trichloroacetic acid solution (1%): Accurately weigh 10 g of trichloroacetic acid into a 1L volumetric flask, dissolve in water and bring to volume, mix well and set aside. 3.2.9 Ammoniated methanol solution (5%): Accurately measure 5 mL of ammonia water and 95 mL of methanol, mix well, and set aside. 3.2.10 Ion pair reagent buffer: Accurately weigh 2.10 g of citric acid and 2.16 g of sodium octanesulfonate, add about 980 mL of water to dissolve, adjust the pH to 3.0, and bring to a constant volume of 1 L for later use. 3.2.11 Melamine standard: CAS 108-78-01, with a purity greater than 99.0%. 3.2.12 Melamine standard stock solution: Accurately weigh 100 mg (accurate to 0.1 mg) of melamine standard into a 100 mL volumetric flask, dissolve it in methanol aqueous solution (3.2.7) and bring it to volume to the mark. Prepare a standard stock solution with a concentration of 1 mg/mL, and store it in dark at 4 ℃

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

BAIJIAN testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Our Competitive Edge:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China

Inquiry:

Facebook

Twitter

LinkedIn

Youtube

instagram

400-101-7153

Skype

WhatsAPP

service@Baijiantest.com

Top