Popular Food Testing


Detection of tetracycline, oxytetracycline, and aureomycin

BAIJIAN - a professional third-party testing and inspection platform that provides relevant testing and inspection services such as tetracycline, oxyt
Product Description:

Determination of Oxytetracycline, Tetracycline, and Chloramphenicol Residues in Livestock and Poultry Meat (High Performance Liquid Chromatography) 1 Scope This standard specifies the detection method for Oxytetracycline, Tetracycline, and Chloramphenicol Residues in Livestock and Poultry Meat. This standard is applicable to the determination of tetracycline and chlortetracycline residues in various livestock and poultry meat. The detection limit of this standard is 0.15 mg/kg for oxytetracycline, 0.20 mg/kg for tetracycline, and 0.65 mg/kg for chlortetracycline. The principle sample is extracted, filtered by a microporous filter membrane, and directly injected. It is separated by reverse phase chromatography, detected by a UV detector, and quantitatively compared with the standard. The peak sequence is oxytetracycline, tetracycline, and chlortetracycline. Standard addition quantification. 3 Reagents 3.1 Acetonitrile (Analytical Purity). 3.2 0.01 mol/L Sodium dihydrogen phosphate solution: Weigh 1.56 g (accurate to ± 0.01 g) of sodium dihydrogen phosphate (NaH, pH · 2HO) and dissolve it in distilled water, dilute to 100 ml, filter through a microporous filter membrane (0.45 pm), and set aside. 3.3 Oxytetracycline (OTC) standard solution: Weigh 0.010 0 g of Oxytetracycline (accurate to ± 0.000 1 g), dissolve it in 0.1 mol/L hydrochloric acid solution, and make a constant volume of 10.00 mL. This solution contains 1 mg of Oxytetracycline per milliliter. 3.4: Tetracycline (TC) standard solution: Weigh 0.0100 g of tetracycline (accurate to ± 0.001 g), dissolve it in 0.01 mol/L hydrochloric acid solution and make a constant volume of 10.00 mL. This solution contains 1 mg of tetracycline per milliliter. 3.5 Chloramphenicol (CTC) standard solution: Weigh 0.0100 g of tetracycline (accurate to ± 0.000 1 g), dissolve it in distilled water and make a constant volume of 10.00 mL. This solution contains 1 mg of tetracycline per milliliter. The above standards are converted to 1000 units/mg. 3.3-3.5 The solution should be stored below 4 ℃ and can be used for one week. 3.6 Mixed standard solution: Take 1.00 mL of 3.3 and 3.4 standard solutions respectively, take 2.00 mL of 3.5 standard solution, place in a 10 mL volumetric flask, and add distilled water to the mark. This solution contains 0.1 mg of oxytetracycline, 0.1 mg of tetracycline, and 0.2 mg of chlortetracycline per milliliter. It should be prepared immediately before use. 3.75% perchloric acid solution

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

BAIJIAN testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Our Competitive Edge:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China

Inquiry:

Facebook

Twitter

LinkedIn

Youtube

instagram

400-101-7153

Skype

WhatsAPP

service@Baijiantest.com

Top