Baijia.net - a professional third-party testing and inspection platform that provides relevant testing and inspection services such as insoluble impur
This standard specifies the method for determining the content of insoluble impurities in animal and vegetable fats. This standard is applicable to animal and vegetable fats. If soaps (especially calcium soaps) or oxidized fatty acids are not calculated as insoluble impurity content, different solvents and operating methods should be used to ensure that the determination of insoluble impurity content meets relevant requirements. 2 Normative References: The clauses in the following documents become clauses of this standard through reference in this standard. For dated reference documents, all subsequent amendments (excluding corrected content) or revisions are not applicable to this standard. Therefore, parties to agreements based on this standard are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest version applies to this standard. GB/T 15687 Preparation of Oil Samples (GB/T 15687-1995. eqv 1SO 6611989) 3 Terms and Definitions The following terms and definitions apply to this standard. 3.1 Insoluble impurities content refers to the amount of substances and foreign impurities that are insoluble in n-hexane or petroleum ether under the conditions specified in this standard. Note 1. The content is expressed as a mass fraction. Note 2. These impurities include mechanical impurities, minerals, carbohydrates, nitrogen-containing compounds, various resins, calcium soaps, oxidized fatty acids, fatty acid and (partially) alkaline soaps, hydroxy fatty acids and their glycerol esters, etc. -4. Dissolve the sample in excess of n-hexane or petroleum ether, filter the obtained test solution, and then rinse the residue and filter paper with the same solvent to dry them at 103 ℃ until the content of insoluble impurities is calculated at constant mass. 5 Reagent warnings; The operating rules for handling hazardous materials should be adopted, and various technical, organizational, and personal safety measures should be followed. Unless otherwise specified, all reagents used are analytical pure. 5.1 n-hexane or petroleum ether: The distillation range of petroleum ether is 30 ℃~60 ℃, and the bromine value is less than 1. The residue of any of the above solvents after complete evaporation should not exceed 0.002 g · 5.2 diatomaceous earth per 100 mL; After purification and calcination, the mass loss is less than 0.2% at 900 ℃ (red hot state). 6. Conventional equipment and testing instruments in the laboratory, including the following instruments. 6.1 Analytical balance: graduation value 0.001 g. 6.2 Electric oven: can be controlled at 103 ℃ soil 2 ℃. 6.3 Conical flask: capacity 250 mL, with ground glass stopper
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms
3. Used as a sales report: issuing legally effective testing reports to make consumers more confident
4. Papers and research: Provide professional personalized testing needs
5. Judicial services: providing scientific, fair, and accurate testing data
6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems
BAIJIAN testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations
3. Mail samples and arrange testing
4. Progress tracking and result feedback
5. Provide reports and after-sales service
6. If urgent or priority processing is required
Our Competitive Edge:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby
3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service
7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc
8. The testing report is authoritative and effective, and is generally used in China
Contact: Mr. Li
Phone: 156-0190-2607
Tel: 400-101-7153
Email: service@Baijiantest.com
Add: No. 700, Yishan Road, Xuhui District, Shangha